T1 - Optimization of Vancomycin Aptamer Sequence Length Increases the Sensitivity of Electrochemical, Aptamer-Based Sensors In Vivo
AU - Shaver, Alexander
AU - Mahlum, J. D.
AU - Scida, Karen
AU - Johnston, Melanie L.
AU - Aller Pellitero, Miguel
AU - Wu, Yao
AU - Carr, Gregory V.
AU - Arroyo-Currás, Netzahualcóyotl
N1 - Publisher Copyright:
© 2022 American Chemical Society.
PY - 2022/12/23
Y1 - 2022/12/23
N2 - The measurement of serum vancomycin levels at the clinic is critical to optimizing dosing given the narrow therapeutic window of this antibiotic. Current approaches to quantitate serum vancomycin levels are based on immunoassays, which are multistep methods requiring extensive processing of patient samples. As an alternative, vancomycin-binding electrochemical, aptamer-based sensors (E-ABs) were developed to simplify the workflow of vancomycin monitoring. E-ABs enable the instantaneous measurement of serum vancomycin concentrations without the need for sample dilution or other processing steps. However, the originally reported vancomycin-binding E-ABs had a dissociation constant of 45 μM, which is approximately 1 order of magnitude higher than the recommended trough concentrations of vancomycin measured in patients. This limited sensitivity hinders the ability of E-ABs to accurately support vancomycin monitoring. To overcome this problem, here we sought to optimize the length of the vancomycin-binding aptamer sequence to enable a broader dynamic range in the E-AB platform. Our results demonstrate, via isothermal calorimetry and E-AB calibrations in undiluted serum, that superior affinity and near-equal sensor gain in vitro can be achieved using a one-base-pair-longer aptamer than the truncated sequence originally reported. We validate the impact of the improved binding affinity in vivo by monitoring vancomycin levels in the brain cortex of live mice following intravenous administration. While the original sequence fails to resolve vancomycin concentrations from baseline noise (SNR = 1.03), our newly reported sequence provides an SNR of 1.62 at the same dose.
AB - The measurement of serum vancomycin levels at the clinic is critical to optimizing dosing given the narrow therapeutic window of this antibiotic. Current approaches to quantitate serum vancomycin levels are based on immunoassays, which are multistep methods requiring extensive processing of patient samples. As an alternative, vancomycin-binding electrochemical, aptamer-based sensors (E-ABs) were developed to simplify the workflow of vancomycin monitoring. E-ABs enable the instantaneous measurement of serum vancomycin concentrations without the need for sample dilution or other processing steps. However, the originally reported vancomycin-binding E-ABs had a dissociation constant of 45 μM, which is approximately 1 order of magnitude higher than the recommended trough concentrations of vancomycin measured in patients. This limited sensitivity hinders the ability of E-ABs to accurately support vancomycin monitoring. To overcome this problem, here we sought to optimize the length of the vancomycin-binding aptamer sequence to enable a broader dynamic range in the E-AB platform. Our results demonstrate, via isothermal calorimetry and E-AB calibrations in undiluted serum, that superior affinity and near-equal sensor gain in vitro can be achieved using a one-base-pair-longer aptamer than the truncated sequence originally reported. We validate the impact of the improved binding affinity in vivo by monitoring vancomycin levels in the brain cortex of live mice following intravenous administration. While the original sequence fails to resolve vancomycin concentrations from baseline noise (SNR = 1.03), our newly reported sequence provides an SNR of 1.62 at the same dose.
KW - aptamer biophysics
KW - aptamer-based sensors
KW - electrochemical biosensors
KW - in vivo
KW - vancomycin
UR - http://www.scopus.com/inward/record.url?scp=85143050312&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85143050312&partnerID=8YFLogxK
U2 - 10.1021/acssensors.2c01910
DO - 10.1021/acssensors.2c01910
M3 - Article
C2 - 36417705
AN - SCOPUS:85143050312
SN - 2379-3694
VL - 7
SP - 3895
EP - 3905
JO - ACS Sensors
JF - ACS Sensors
IS - 12
ER -