TY - GEN
T1 - Novel configuration for an AC electroosmotic pump driven by AC voltage with DC voltage bias for bi-directionality and increased volumetric flow rates
AU - Stoterau, Shane
AU - Ciocanel, Constantin
AU - Islam, Nazmul
AU - Kipple, Allison
PY - 2010
Y1 - 2010
N2 - This paper discusses the principle of AC electroosmosis and its use to move the bulk of an electrically conducting fluid in a microchannel as an alternative to mechanical pumping methods. Previous EO driven flow research [1-3] has looked at the effect of electrode asymmetry and transverse traveling wave forms on the performance of electroosmotic pumps. This paper presents an analysis that was conducted to assess the effect of combining an AC signal with a DC bias when generating the electric field needed to impart electroosmosis within a micro-channel [4]. The analysis was done using COMSOL 3.5a in which previously developed equations [1-2] were embedded and used to evaluate the effects of the frequency of excitation, electrode array geometry, and the AC signal with a DC bias on the flow imparted on an electrically conducting fluid. A single type of fluid was simulated to date. For the AC driven flow, the simulation results indicate the existence of an optimized frequency of excitation and an optimum geometry that lead to the maximum net forward flow of the pump. For a specified set of constants [electric conductivity (2.1 mS/m), lagging electrode width (220 μm), micro-channel height (200 μm), applied AC voltage (0.25 V), electrode array gap (290 μm), and etc], the optimum frequency was 250 Hz and the optimum geometry consisted of a preceding electrode width of 60 μm with an inter electrode gap of 30 μm. No relevant net flows were generated with the asymmetric electrode arrays with a constant magnitude of AC voltage applied to both electrodes. However, superimposing a DC signal over the AC signal on the same asymmetric electrode array lead to a noticeable net forward flow of 18.70 μL/min. Experimental flow measurements were performed on several pump configurations manufactured using typical MEMS fabrication techniques. The experimental results are in good agreement with the simulation data. They confirm that using an asymmetric electrode array excited by an AC signal with a DC bias leads to a significant improvement in flow rates in comparison to the flow rates obtained in an asymmetric electrode array configuration excited just with an AC signal.
AB - This paper discusses the principle of AC electroosmosis and its use to move the bulk of an electrically conducting fluid in a microchannel as an alternative to mechanical pumping methods. Previous EO driven flow research [1-3] has looked at the effect of electrode asymmetry and transverse traveling wave forms on the performance of electroosmotic pumps. This paper presents an analysis that was conducted to assess the effect of combining an AC signal with a DC bias when generating the electric field needed to impart electroosmosis within a micro-channel [4]. The analysis was done using COMSOL 3.5a in which previously developed equations [1-2] were embedded and used to evaluate the effects of the frequency of excitation, electrode array geometry, and the AC signal with a DC bias on the flow imparted on an electrically conducting fluid. A single type of fluid was simulated to date. For the AC driven flow, the simulation results indicate the existence of an optimized frequency of excitation and an optimum geometry that lead to the maximum net forward flow of the pump. For a specified set of constants [electric conductivity (2.1 mS/m), lagging electrode width (220 μm), micro-channel height (200 μm), applied AC voltage (0.25 V), electrode array gap (290 μm), and etc], the optimum frequency was 250 Hz and the optimum geometry consisted of a preceding electrode width of 60 μm with an inter electrode gap of 30 μm. No relevant net flows were generated with the asymmetric electrode arrays with a constant magnitude of AC voltage applied to both electrodes. However, superimposing a DC signal over the AC signal on the same asymmetric electrode array lead to a noticeable net forward flow of 18.70 μL/min. Experimental flow measurements were performed on several pump configurations manufactured using typical MEMS fabrication techniques. The experimental results are in good agreement with the simulation data. They confirm that using an asymmetric electrode array excited by an AC signal with a DC bias leads to a significant improvement in flow rates in comparison to the flow rates obtained in an asymmetric electrode array configuration excited just with an AC signal.
UR - http://www.scopus.com/inward/record.url?scp=77955756829&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=77955756829&partnerID=8YFLogxK
U2 - 10.1109/UGIM.2010.5508900
DO - 10.1109/UGIM.2010.5508900
M3 - Conference contribution
AN - SCOPUS:77955756829
SN - 9781424447329
T3 - Biennial University/Government/Industry Microelectronics Symposium - Proceedings
BT - 2010 18th Biennial University/Government/Industry Micro-Nano Symposium, UGIM 2010 - Proceedings
T2 - 18th Biennial University/Government/Industry Micro-Nano Symposium, UGIM 2010
Y2 - 28 June 2010 through 1 July 2010
ER -